Typical application: ROHS tester, XRF tester: an alternative to XRM50P503839, XRM50P503768, XRM50P503491, XRM50P503465, Elemental analysis: an alternative to XRM50P502871, XRM50P502810, XRM50P503830, Thickness detection Density measurement PCB appearance inspection machine X-RAY inspection machine PCB drilling target drone 1.1 XRW Series Introduction XRM series high voltage power supply for X ray tube provides advanced and complete solution.This power is not only provide high voltage output, also provides complete control signal and a variety of auxiliary functions, so as to meet the need of application of X ray tube.XRM series power can output a stable small ripple voltage and current, make its performance than previous techniques has greatly improved, with no increase in X ray tube load under the condition of better focus. The series 1.2 XRW specification Input: DC DC24V ± 10%, maximum current 4.25A. Output: 20KV, 30KV, 50KV, 65KV four maximum voltage output optional, 0V to the highest voltage adjustable. Voltage control: The internal power supply: power supply with multiturn potentiometer can be output Voltage setting in the 0V to the highest voltage External remote control: external 0 to 10V control signals can be output From the 0V to the maximum output voltage. Emission current control: The internal power supply: power supply with multiturn potentiometer can be set in the 0A electron beam current to a maximum current. External remote control: external 0 to 10V control signals can be set in the 0A electron beam current to a maximum current. DC filament power supply: output current of 0-3.5A adjustable voltage, adjustable for 0-5.5V. Voltage regulation rate: Relative load: 0.01% (no load to rated load) The phase of input: ± 0.01% (input voltage change is ± 10%) Current regulation: Relative load: 0.01% (no load to rated load) Relative to the input: ± 0.01% (input voltage variations of ± 10%) Output ripple voltage: rated voltage condition, the ripple voltage peak value for the maximum output voltage 0.25%. Temperature coefficient: 0.01% per degree celsius. Stability: starting up half hours after every 8 hours less than 0.05%. Voltage current instruction: 0 to +10V, rated output condition accuracy of 1%. Environment temperature: 0 ℃ to +50 ℃ when working.Storage at -20 ℃ to +80 ℃. Dimensions: length 254MM, width 100mm, high 160mm. Weight: 4.8 kg. Connector: High voltage output connector: recessed insulating epoxy resin duct and into the high voltage cable through the diameter of 16mm metal connector.High voltage cable length of 1 meters. Input output connector: DB9 contains the control and display signal. Output voltage and current of the remote control: external potentiometer can be used inside power supply 10V reference voltage on the output voltage and current for remote control. Remote voltage indication: JP4 contains 0 10V voltage and current indicative signal, can be externally connected with various number or pointer table. 1.3 standard function The XRW series offers a standard function to meet the user's application and security needs. High voltage, high current and filament current slow start function: this function makes the high voltage output, high voltage current and filament current according to the design requirements of slope rises smoothly, thereby prolonging the service life of X ray tube, usually the rise time is about 4 seconds, the filament current will rise slowly until the emission current at required level.When the output is the maximum value, this time is generally 4 seconds.The ramp starting conditions for the triggering of INTERLOCK control signal. Light emitting diode lamp: green light-emitting diode power indicator, yellow for high voltage output off indicator, red for high voltage output indicator. High voltage cable: standard power supply provides a 1 meters high voltage insulated cable, one end of the cable with a plug and a very easy to be fixed on the shell of the connector for power supply.For non standard power refer to diagram and description. 1.31 remote monitoring function: Remote detection: by detecting the front panel of the KV MON and MON RTN and mA MON and MON RTN X ray tube voltage and emission current remote detection function.Standard products for the KV MON 1V=10KV, mA MON 1V=0.1 mA (other proportion of optional) |