30KV high voltage power supply use for electrophresis

Click image to view original image
Brand: Wisman
型号: MT
Price: Negotiable
Min.Order: 1 pcs
Supply 10000000 pcs
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2014-09-15 15:22
Hits: 3474987
Enquiry
Company Detail
 
 
Details
 Product Name MT

Power(W)5W-30W,60W

Output Voltage(KV)  0.3KV-30KV


SUMMARY

The MT serise ie a regulated, versatile,modular HV power supply used in a wide variety of applications  including MTss spectrometry and Electron Microcopes.From the OEM to the laboratory,they are an excellent choice when you require a highiy stable output.Output can be controlled using either an external control voltage or external variable resistor.With a diverse range of models up to 6KV/30W,you will find something for nearly every requirement.


SPECIFICATIONS

Input Voltage:

12Vdc for 5W, 24Vdc for 10W,30W and 60W.

Nominal Voltage Range:

11Vdc to 30Vdc for 5W, 23Vdc to 30Vdc for 10W,30W and 60W.

Input Curr ent: (typical)

Disabled: 30mA

No load: 90mA

Full load:

5 watt units: 0.5A

10 watt units: 1.0A

30 watt units: 1.5A

60 watt units: 3.5A

Efficiency:

80-85%, typical

Voltage Re gulation:

Line: <0.01%

Load: <0.01%

Current Re gulation:

Line: <0.01%

Load: <0.01%

Output Voltage:

Continuously adjustable over entire output range. Available

in either positive or negative output polarity. See table for

voltage ranges.

Output Voltage Control: Controlled by either:

1) External potentiometer 100k (set internal pot. to MTx.)

2) Remote differential voltage programming (0 to +5V gives

0 to full output).

Accur acy:

2% on all programming and monitoring,

Temperature Coefficient: (typical)

Optional: 25ppm/°C (T Option)

Environmental:

Temperature Range:

Operating: -40°C to 65°C case temperature

Storage: -55°C to 85°C, non operational

Humidity:

10% to 90%, non-condensing.

Cooling:

Convection cooled, typical. 60 watt units operating at full power

might require additional cooling to maintain case temperature

below 65°C. Methods may include: forced air cooling, use of

heat sink or metal case, etc. It is the user’s responsibility to

maintain the case temperature below 65°C. Damage to the

power supply due to inadequate cooling is considered misuse

and repairs will not be covered under warranty.

Dimensions:

See table

Weight:

See table

Total: 0 [Show All]  Related Reviews
 
More »Our Others Products